HOME      Email


Vacuum Transducers for Digital Acquisition or PLCs


0-30" Mercury Vacuum Pressure Transmitters
HyVac has a number of pressure transducers in the low vacuum range that can be either hooked up to a programmable logic controller (PLC) or a digital acquisition (DA) system. The models are available with output in either 4-20 milliAmp or 1-5 volt output The transmitter is housed in a metal NEMA 5 approved enclosure. Because the output ranges from 0 to 30" hg vacuum or scale can be adapted to other scales. Use these economical pressure transmitters with clean, dry non-corrosive gases. These units are ideal for both your laboratory and industrial application. Solid-state design ensures reliability and provides an accuracy of +/-1%. Choose a transmitter with either 4-20 ma or 1-5 v output signal. Select a 4-20 ma model for excellent performance in noisy electrical environments; the transmitter uses a two-wire current loop system. Color-coded wiring makes installation easy. Units have a 1/8" MNPT brass fitting for incorporation into systems.

Specifications
Accuracy: +/- 1% full scale
Temperature range: (compensated): 0 to 160 Deg F (-17 to 71 Deg C)
Process connection: 1/8" male npt
Power:  4 to 20 ma transmitters: 10 to 30 volts dc
                1 to 5 v transmitters: 6 to 32 volts dc
Electrical connection: 36" shielded cable
Media compatibility: clean, dry, non
-corrosive gases
Dimensions: 1 3/4" L x 1 1/2" Diameter
Shipping wt: 1 lb (0.5Kg)


SEALED STAINLESS STEEL PRESSURE TRANSMITTERS

Compound Ranges Available 30" Hg To 0 Psig
Reverse Polarity Protected
NIST-Traceable Accuracy
Stainless Steel Diaphragm And Polysilicon Strain Gauge
Are Bonded By Vapor Deposition No Epoxies Or Glues Which Can Cause Signal Instability Or Drift.
Case And Wetted Parts Are Constructed Of 300-Series Stainless Steel.
Choose 4-20 Ma Or 1-5 vDC Output Signal With +/- 0.4% Or +/- 0.25% Accuracy (Bfsl).
Operating Temperature Range Is -20 To 180f (-29 To 82c).
Models 68001-04 Through - 34 Come With A Calibration Certificate Ensuring NIST-Traceable Accuracy.

SPECIFICATIONS

TEMPERATURE RANGE (COMPENSATED): -20 TO 160F (-29 TO 71C)
PROCESS CONNECTION: 1/4" NPT(M)
POWER:
12 TO 30 VDC
ELECTRICAL CONNECTION: 36:L SHIELDED CABLE
MEDIA COMPATIBILITY: GASES OR LIQUIDS COMPATIBLE WITH 300 SERIES SS
DIMENSIONS: 3"L X 1" DIAMETER
SHPG WT:
1LB (0.5KG)

We also have digital gauges and software to do aquisition via RS232 ports

There are a number of these products available.  I have included some pictures
of the more interesting types and styles.  The specifications above are available
in one form or another but may not be connected with the pictures below.

This is a 0-30 Mounted on snap track 0-30 with a digital display
0-30 No Display with RS232 out 0-30 with no display
0-30 digital display

11/30/2005 ©Copyright HyVac Products, Inc. All Rights Reserved
Toll Free 1-800-628-0850